Immunofluorescence Analyzer (TRFIA)
Immunofluorescence Analyzer (TRFIA)
Product Video
Key Attributes
Product Name | Immunofluorescence Analyzer (TRFIA) |
Brand Name | Konsung |
Type | Blood analysis system |
Model Number | Compass 3000 |
Instrument Classification | Class II |
Warranty | 3 Years |
Input | 100-240V,50/60Hz ,30VA; |
Output | DC 5V,2A |
Inner Power | DC 3.7V |
Work Environmental Temperature | 0 ℃ ~40 ℃ |
Inspection Method | Photometric detection |
Sample Dosage | 40ul |
Inspection Time | ≤3min |
Type of Sample | Capillary vessel or vein |
After-sale Service | Online technical support |
Test Items
Inflammation
CRP
Measurement: 0.5~150 mg/L
Sample: whole blood, serum, plasma
Sample Volume: 10 μL
Reaction Time: 3 mins
CRP/SAA
Measurement: CRP 5~150 mg/L; SAA 5~150 mg/L
Sample: serum, whole blood, plasma
Sample Volume: 10 μL
Reaction Time: 5 mins
PCT
Measurement: 0.1~50 ng/mL
Sample: serum, plasma, whole blood
Sample Volume: 100 μL (serum, plasma), 150 μL (whole blood)
Reaction Time: 15 mins
Cardiac Markers
NT-proBNP
Measurement: 30~30000 pg/mL
Sample: serum, plasma, whole blood
Sample Volume: 100 μL (serum, plasma), 150 μL (whole blood)
Reaction Time: 10 mins
D-Dimer
Measurement: 0.1~10 mg/L
Sample: whole blood, plasma
Sample Volume: 150 μL (whole blood), 100 μL (plasma)
Reaction Time: 10 mins
cTnI
Measurement: 0.1 ng/mL~50 ng/mL
Sample: serum, plasma or whole blood
Sample Volume: 100 μL
Reaction Time: 15 mins
cTnI/CK-MB/MYO
Measurement: cTnI: 0.1 ng/mL ~50 ng/mL; Myo: 2 ng/mL ~400 ng/mL; CK-MB: 1.0 ng/mL ~100 ng/mL
Sample: serum, plasma or whole blood
Sample Volume: 100 μL
Reaction Time: 15 mins
Diabetes Mellitus
HbA1c
Measurement: 4 ~ 14%
Sample: whole blood
Sample Volume: 10 μL
Reaction Time: 10 mins
Thyroid Function
TSH
Measurement: 0.1 mIU/L~ 10 mIU/L
Sample: serum, plasma
Sample Volume: 100 μL
Reaction Time: 15 mins
T3
Measurement: 0.5 ng/mL ~5.0 ng/mL
Sample: serum, plasma
Sample Volume: 100 μL
Reaction Time: 15 mins
T4
Measurement: 10 ng/mL ~ 240 ng/mL
Sample: serum, plasma
Sample Volume: 100 μL
Reaction Time: 15 mins
Fertility
β-HCG
Measurement: 4 ~10000 mIU/L
Sample: serum, plasma
Sample Volume: 100 μL
Reaction Time: 15 mins
Others
25-OH-VD
Measurement: 5 ~120 ng/mL
Sample: serum, plasma
Sample Volume: 20 μL
Reaction Time: 15 mins
Ferritin
Measurement: 6~100 ng/mL
Sample: whole blood, plasma
Sample Volume: 150 μL (whole blood), 100 μL (plasma)
Reaction Time: 10 mins
Analyzer Features
14 tests on 1 analyzer
4.3” touch screen
Testing Procedure of Fingertip Blood
Insert the code chip for calibration.
Draw sufficient amount of fingertip blood and mix with buffer.
Dispense the mixed blood sample to the test card and starting testing.
Insert the test card and check test results.
Packaging & Delivery
Packaging Details | Packing in carton, one piece of device including full set of consumables for 100 persons/immunofluorescence analyzer (TRFIA) |
Port | Shanghai port |
Selling Units | Single item |
Single Package Size | 19X10X10 cm |
Single Gross Weight | 0.750 kg |
To better ensure the safety of your goods, professional, environmentally friendly, convenient and efficient packaging services will be provided. |