China OEM 64 Beds Hospital Wireless Central Monitor System – Aurora-8 8.4 inch multi parameter patient monitor for ambulance and transport – Konsung
China OEM 64 Beds Hospital Wireless Central Monitor System – Aurora-8 8.4 inch multi parameter patient monitor for ambulance and transport – Konsung Detail:
Aurora-8 8.4-inch multi parameter patient monitor for ambulance and transport
Patient monitor
Product Detail:
◆Indication of incorrect manipulation and malfunction analysis
◆Patient info input management function
◆Multi-lead ECG waveforms display in phase
◆Large volume of tabular and graphic trends information storage and easy to recall
◆Capture dynamic waveforms
◆Up to 5 hours working capacity of built-in rechargeable lithium battery
◆Unique accessory management cabinet
Networking capacity
◆Option: EtCO2, 5AH Lithium battery, wireless communication module (WIFI, GPRS), touch screen, IBP, AG.
Accessories:
Technique Parameter
Standard configuration |
|
Screen |
|
Display Type | 8″ color TFT LCD |
Resolution | 800×600 pixels |
Waveforms | Up to 7 |
ECG |
|
Input | 3/5 wire ECG cable |
Lead section | I II III aVR, aVL, aVF, V |
Gain selection | *0.25, *0.5, *1, *1.2 |
Sweep speed | 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s |
Heart rate range | 15-30bpm |
Calibration | ±1mv |
Accuracy | ±1bpm or ±1% (select the bigger data) |
NIBP |
|
Test method | Oscillometer |
Philosophy | Adult, Pediatric and Neonate |
Measurement type | Systolic Diastolic Mean |
Measurement parameter | Automatic, Continuous measurement |
Measurement method Manual | mmHg or ±2% |
SPO2 |
|
Display Type | Waveform, Data |
Measurement range | 0-100% |
Accuracy | ±3% (between 70%-100%) |
Pulse rate range | 20-300bpm |
Accuracy | ±1bpm or ±2% (select the bigger data) |
Resolution | 1bpm |
2-Temperature (Rectal & Surface) |
|
Number of channels | 2 channels |
Measurement range | 0-50℃ |
Accuracy | ±0.2℃ |
Display | T1, T2, ☒T |
Unit | ºC/ºF selection |
Refresh cycle | 1s-2s |
Respiration (Impedance & Nasal Tube) |
|
Measurement type | 0-150rpm |
Accuracy | ±1bm or ±5%, select the bigger data |
Resolution | 1rpm |
Optional configuration |
|
EtCO2-Plug & Play |
|
Measurement type | Side stream |
Measurement range | 0-10.0%; 0-76mmHg |
Accuracy | <5.0%, ±0.28kPa; ±2mmHg |
>5.0%, ±10% | |
2-IBP (optional) |
|
Measurement range | 10~300mmHg |
Number of channels | 1 or 2 channels |
Accuracy | ±1mmHg or ±2%, select bigger data |
Pressure tag | ART, CVT, RVP, LAP, RAP, PAP, ICP, LVP |
12 leads ECG (optional) |
|
Input | 3/5/10 wires ECG cable |
Lead section | I, II, III aVR, aVL, aVF, V(V1-V6) |
Heart rate range | 15-380bpm |
Calibration | ±1mv |
Product detail pictures:
Related Product Guide:
We believe that long expression partnership is often a result of top of the range, value added service, prosperous encounter and personal contact for China OEM 64 Beds Hospital Wireless Central Monitor System – Aurora-8 8.4 inch multi parameter patient monitor for ambulance and transport – Konsung, The product will supply to all over the world, such as: Lyon, Senegal, Mauritius, Profession, Devoting are always fundamental to our mission. We have always been in line with serving customers, creating value management objectives and adhering to the sincerity, dedication, persistent management idea.
By Bernice from UK - 2018.12.11 14:13
The enterprise has a strong capital and competitive power, product is sufficient, reliable, so we have no worries on cooperating with them.
By Ellen from Frankfurt - 2018.05.13 17:00