AURORA-10S 10.4-inch lightweight wireless patient monitor with printer Masimo SpO2 option
Patient monitor
Product Detail:
◆Indication of incorrect manipulation and malfunction analysis
◆Patient info input management function
◆Multi-lead ECG waveforms display in phase
◆Large volume of tabular and graphic trends information storage and easy to recall
◆Capture dynamic waveforms
◆Up to 5 hours working capacity of built-in rechargeable lithium battery
◆Unique accessory management cabinet
◆Networking capacity
◆Option: EtCO2, 5AH Lithium battery, wireless communication module (WIFI, GPRS), touch screen, IBP, AG.
Accessories
Optional modular
Technique parameters
Standard configuration |
|
Screen |
|
Display Type | 10″ color TFT LCD |
Resolution | 800×600 pixels |
Waveforms | Up to 7 |
ECG |
|
Input | 3/5 wire ECG cable |
Lead section | I II III aVR, aVL, aVF, V |
Gain selection | *0.25, *0.5, *1, *1.2 |
Sweep speed | 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s |
Heart rate range | 15-30bpm |
Calibration | ±1mv |
Accuracy | ±1bpm or ±1% (select the bigger data) |
NIBP |
|
Test method | Oscillometer |
Philosophy | Adult, Pediatric and Neonate |
Measurement type | Systolic Diastolic Mean |
Measurement parameter | Automatic, Continuous measurement |
Measurement method Manual | mmHg or ±2% |
SPO2 |
|
Display Type | Waveform, Data |
Measurement range | 0-100% |
Accuracy | ±3% (between 70%-100%) |
Pulse rate range | 20-300bpm |
Accuracy | ±1bpm or ±2% (select the bigger data) |
Resolution | 1bpm |
2-Temperature (Rectal & Surface) |
|
Number of channels | 2 channels |
Measurement range | 0-50℃ |
Accuracy | ±0.2℃ |
Display | T1, T2, ☒T |
Unit | ºC/ºF selection |
Refresh cycle | 1s-2s |
Respiration (Impedance & Nasal Tube) |
|
Measurement type | 0-150rpm |
Accuracy | ±1bm or ±5%, select the bigger data |
Resolution | 1rpm |
Optional configuration |
|
EtCO2-Plug & Play |
|
Measurement type | Side stream |
Measurement range | 0-10.0%; 0-76mmHg |
Accuracy | <5.0%, ±0.28kPa; ±2mmHg |
>5.0%, ±10% | |
2-IBP (optional) |
|
Measurement range | 10~300mmHg |
Number of channels | 1 or 2 channels |
Accuracy | ±1mmHg or ±2%, select bigger data |
Pressure tag | ART, CVT, RVP, LAP, RAP, PAP, ICP, LVP |
12 leads ECG (optional) |
|
Input | 3/5/10 wires ECG cable |
Lead section | I, II, III aVR, aVL, aVF, V(V1-V6) |
Heart rate range | 15-380bpm |
Calibration | ±1mv |
Product detail pictures:
Related Product Guide:
Bear Customer initially, High quality first in mind, we do the job closely with our customers and supply them with efficient and skilled providers for China OEM 64 Beds Hospital Wireless Central Monitor System – AURORA-10S 10.4 inch lightweight wireless patient monitor with printer Masimo Spo2 option – Konsung, The product will supply to all over the world, such as: Kazakhstan, Peru, Bahamas, Our staffs are rich in experience and trained strictly, with qualified knowledge, with energy and always respect their customers as the No. 1, and promise to do their best to deliver the effective and individual service for customers. The Company pays attention to maintaining and developing the long-term cooperation relationship with the customers. We promise, as your ideal partner, we'll develop a bright future and enjoy the satisfying fruit together with you, with persisting zeal, endless energy and forward spirit.