non-mercury medical blood pressure monitors with LCD screen

Short Description:

◆There is high simulation mercury sensor on the blood pressure monitor, the working principle is analog signal transfer into a digital signal by their owned algorithms, the blood pressure acts on the sensor and transfer it into the digital signal. Meanwhile, there is a high simulation mercury sensor on the blood pressure monitor, and it assures the accuracy-test result, more and more doctors would like to this type of blood pressure monitor.


Product Detail

Non-mercury medical blood pressure monitors with LCD screen

non-mercury medical blood pressure monitors with LCD screen

Blood pressure monitor

Product Detail:

Lightweight and portable, classical strip design, including storage box of cuff, foldable screen, foldable and easy storage.

◆Humanization cuff with comfortable and soft, easy to operate, the tightness of cuff will be adjusted by inner Velcro, and it suitable to people of different constitution.

◆There is a big screen with high definition, and it will show test result clearly, even though easy to read for the elders who are poor eyesight.

Medical grade. The blood pressure is medical devices which is controlled strictly by medical standard, more comfortable to use.

The D-Manometer is a replacement of traditional mercury sphygomanometer, it is built with advanced digital technologies to test the blood pressure, it does not contain mercury or lead. It has same use way as mercury sphygmomanometer and has same accuracy. Please use the machine with a stethoscope together!

Q-Manometer contains parts as bellow: Manometer, Cuff, Hand pump and valve, stethoscope and user manual.

Specification:

Model: QD103

◆Power supply: 2 size “AA” battery

◆Battery life: 5000 measurement cycle

◆Working temperature: 5℃-45℃

◆Range of pressure measurement: 0-300mmHg

◆Range for PR measurement: 40-200 times/min

◆Pressure accuracy rating: ±3mmHg

◆Measure method: 99 sets

◆Dimensions: 32.5cm×9cm×6cm        

Weight: 800g

Caution:

◆Make sure that the upper arm is at the heart level of the patient. Otherwise, the measurement result may be inaccurate.

◆Applying the cuff: Wrap the correctly sized cuff evenly and snugly around the upper arm, but there should be enough room for you to slip a fingertip under the cuff. Make sure that the artery mark on the cuff is positioned over the brachial artery, and the bottom edge of the cuff is positioned about 3 cm above the crease of the elbow. Make sure that the index line fall between the two range lines, which indicates that the cuff fits the upper arm properly. Otherwise, change the cuff with an appropriate size.

◆Position the stethoscope: Place the film side of the stethoscope disk on the inner side of the crease of the elbow.

◆Open the value to deflate the cuff completely. The measurement result may be inaccurate if the D-Manometer is powered on with residual pressure in the cuff.

◆Press the Power button to turn on the machine. it will firstly do zero calibration and display ‘888’ on the LCD screen. This process will not complete until the cuff pressure is stable. When this process completes (display of ‘888’ disappears), it is ready to measure.